User Manual for APC BE600M1 Back-UPS with Battery Backup Click to enlarge the picture
Contents of the user manual for the APC BE600M1 Back-UPS with Battery Backup
- Product category: UPS Backup APC
- Brand: APC
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for APC UPS Backup
|
User manual for the APC BE600M1 Back-UPS with Battery Backup contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any APC product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official APC user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a APC product will considerably shorten its lifespan!
|
Product description - BE600M1 BACK-UPS ES 600VA 120V-1 USB CHRG PORT
Protect up to 7 devices from power surges and spikes with the BE600M1 Back-UPS 600 VA UPS with Battery Backup from APC. This uninterruptible power supply features 7 AC outlets and a USB port to safely provide power to up to 8 devices. Audible alarms indicate changes in power, battery failure, wiring problems, and if a battery was disconnected in order to keep you informed. Additionally, there are LED indicators to quickly inform you of the status of the unit. General Features - 600 VA / 330W power rating
- Simulated sine wave UPS with battery
- Adjustable voltage sensitivity provides the ability to adapt the UPS for optimal performance in varying environments
- Automatic self-test ensures early detection of failing batteries
- Battery failure notification provides an early warning of when a battery is dying
- Building wiring fault indicator informs users of potentially dangerous wiring
- The unit can provide temporary battery power when utility power is lost
- Hot-swappable batteries allow for easy battery replacement without losing power
- Transformer block spacing provides enough space for larger power adapters
- Intelligent battery management ensures efficient battery maintenance
- Five battery backup outlets and two surge-only outlets
- $75,000 equipment protection policy against damaged connected equipment
UPC: 731304325116 In the Box APC BE600M1 Back-UPS with Battery Backup Lifetime $75,000 Equipment Protection Policy Limited 3-Year Warranty More from Manufacturer zedxvfauytudstzxvszaetxawwzyzyrreqtybc More info from APC Table of Contents
|
Upload User Manual
Have you got an user manual for the APC BE600M1 Back-UPS with Battery Backup in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersAPC BE600M1 Specs | | | Total Outlets | 7 x NEMA 5-15R | | Protected Outlets | 5 x NEMA 5-15R (Battery and Surge) 2 x NEMA 5-15R (Surge Only) | | Plug Type | NEMA 5-15P Right-Angle | | USB Charging Ports | 1 x USB Type-A (1.5 A) | | Communications | USB | | Noise Filtering | 5% | | Topology | Standby | | Transfer Time | 6 to 10 ms | | | | Surge Energy Rating | 490 Joules | | Maximum Wattage | 330 W | | Nominal Input Voltage | 120 VAC | | Input Voltage Range | 92 to 139 VAC | | Input Voltage Adjustable Range | 88 to 142 VAC | | Input Frequency | 50/60 Hz ± 3 Hz (Auto Sensing) | | Nominal Output Voltage | 120 VAC | | Load Capacity | 600 VA | | Circuit Breaker Rating | 15 A | | Thermal Dissipation | 16 BTU/Hour | | Waveform | Simulated Sine Wave | | | | Chemistry | Lead-Acid | | Charging Time | 10 Hours | | Replacement Battery | APCRBC154 | | Hot-Swap Support | Yes | | | | Operating Temperature | 32 to 104°F / 0 to 40°C | | Operating Humidity | 0 to 90% | | Storage Temperature | 5 to 113°F / -15 to 45°C | | Storage Humidity | 0 to 95% | | Storage Altitude | 50,000' / 15,000 m | | Noise Level | 35 dBA | | | | Cable Length | 5' / 1.5 m | | Dimensions (W x H x D) | 5.5 x 4.1 x 10.8" / 14.0 x 10.5 x 27.4 cm | | Weight | 7.7 lb / 3.5 kg | | | | Package Weight | 8.65 lb | | Box Dimensions (LxWxH) | 14.2 x 7.7 x 6.6" |
Rating92% users recommend this product to others. And what about you?

This product has already been rated by 19 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
NEWER F100 CAMERA MONITOR... PhotoStage progessional... powerpint... Night Detective Quest 5M 5x Night Vision Monocular ... Ibanez AM93QM User Manual....
|
| Discussion |
Latest contributions to the discussion:
TR-P5TP pink robot dog Name: Allyson Top Race Race & Remote Control Hello we are having issues with the remote to the robot dog it just flashes a red light will not sync to the robot dog what so ever the dog is charged and batteries have been changed out more the once, Can i get help trouble shooting the issue or if something needs to be sent bac... Query Name: Libba Guyton Canon Pixma TS9520 Wireless All-In-One Printer Support Code 1851
Multi purpose tray guide is open. Close the guide and press OK.
Done and the same message continue to appear.... Manual Name: Grant Konus KonuStart-700B 60mm f 11.6 Refractor Please send user manual for Konustart-700B to above email address.... Fs3x manual Name: Randy Reid DigiTech FS3X Three-Function Foot Switch I need manual
... adding additional chime Name: Stan Stansfield OhmKat Video Doorbell Power Supply for The additional chime does not work and is closure to the transmitter then the first one. I plugged in the additional chime and set the volume and chime. The original chime works when the additional chime is plugged in to new location. The original chime is located further away bu...
|
|