User Manual for APC Line-R 1200VA Automatic Voltage Regulator Click to enlarge the picture
Contents of the user manual for the APC Line-R 1200VA Automatic Voltage Regulator
- Product category: Power Distributors & Conditioners APC
- Brand: APC
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for APC Power Distributors & Conditioners
|
User manual for the APC Line-R 1200VA Automatic Voltage Regulator contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any APC product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official APC user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a APC product will considerably shorten its lifespan!
|
Product description The Line-R 1200VA Automatic Voltage Regulator from APC provides automatic voltage regulation (AVR) to help protect against brownouts and overvoltages. It features an output power capacity and a max configurable power of 1200 VA / 1200W, a nominal output voltage of 120 VAC, a nominal input voltage of 120 VAC at 50/60 Hz, and a surge energy rating of 680 joules. It utilizes four NEMA 5-15P input connections and a 6.5' power cord. While the unit itself is protected by a limited 2-year repair or replace warranty, any gear connected to this unit is protected by a limited $25,000 equipment-protection policy. General Features Convenience - Status-Indicator LEDs
- LED status indicators for each phase and an audible alarm provide immediate failure notification when surge-suppression circuitry has been damaged by a heavy strike or surge
- Transformer-Block Spacing
- Connect bulky transformer-block plugs without covering up other outlets
Protection - Resettable Circuit Breaker
- Easy recovery from overloads; no need to replace a fuse
- Automatic Voltage Regulation (AVR)
- Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment
- Lightning and Surge Protection
- To help prevent damage to your equipment from electric power surges and spikes
Product Distribution - Countries
- Aruba, Barbados, Belize, Canada, Colombia, Costa Rica, Dominican Republic, Ecuador, Guatemala, Guyana, Honduras, Jamaica, Mexico, Nicaragua, Panama, Puerto Rico, El Salvador, Trinidad and Tobago, United States, and Venezuela
UPC: 731304197911 In the Box APC Line-R 1200VA Automatic Voltage Regulator Limited Lifetime $25,000 Equipment Protection Policy Limited 2-Year Repair or Replace Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the APC Line-R 1200VA Automatic Voltage Regulator in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersAPC LE1200 Specs | | | Output Power Capacity | 1200 VA / 1200 W | | Max Configurable Power | 1200 VA / 1200 W | | Nominal Output Voltage | 120 VAC | | | | Nominal Input Voltage | 120 VAC | | Input Frequency | 50/60 Hz | | Input Connections | NEMA 5-15P | | Cord Length | 6.5' / 2.0 m | | Number of Power Cords | 1 | | | | Surge Energy Rating | 680 joules | | | | Operating Environment | 32 to 104°F / 0 to 40°C | | Operating Relative Humidity | 5 to 95% | | Operating Elevation | 0 to 10,000' / 0 to 3,048 m | | Storage Temperature | -13 to 149°F / -25 to 65°C | | Storage Relative Humidity | 5 to 95% | | Storage Elevation | 0 to 50,000' / 0 to 15,240 m | | | | Approvals | cUL Listed, FCC Part 15 Class B, NOM, UL 1012 | | | | Color | Beige | | Dimensions (H x W x D) | 4.55 x 8.43 x 5.55" / 11.56 x 21.41 x 14.1 cm | | Weight | 9.68 lb / 4.39 kg | | | | Package Weight | 10.0 lb | | Box Dimensions (LxWxH) | 11.5 x 8.5 x 7.5" |
Rating92% users recommend this product to others. And what about you?

This product has already been rated by 69 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
Post new comment to APC Line-R 1200VA Automatic Voltage Regulator
| Subject: ACE R-1200 | | Date: 13.02.2022 19:54:38 | Name: Norma Rivera | on which of the 3 setting should the regulator be set for home tv use: 110v, 120v, 127v???
Tv is new; don't want it to ruin it!! | | Post reply |
| Subject: ACE R-1200 | | Date: 13.02.2022 19:54:37 | Name: Norma Rivera | on which of the 3 setting should the regulator be set for home tv use: 110v, 120v, 127v???
Tv is new; don't want it to ruin it!! | | Post reply |
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
inspiron 3470... Film Scanner 8 mm + super 8 REELS MOVIE MAKER PRO... HP 3630 deskjet printer/scanner... Dell KB216 ITALIAN Slim Office Multimedia Keyboard BLACK.
... Mistral MC2300R 25L Detachable Air Coller with Steriliser.
Thank you in advance for your assistance.
Sincerely,
Jonathan Chua...
|
| Discussion |
Latest contributions to the discussion:
Instructions for assembling the 2015 Forecast Image Master Consoles GC3-A Name: mike elam Forecast Consoles GC3-A ImageMaster Editing Console Looking for instructions for assembling this console. ... EMPTY TONER ERROR MESSAGE AFTER REPLACING TONER Name: LINDA BAD YELLOW EYES Brother TN223BK Standard-Yield Toner I HAD TO CHANGE OUT ALL THREE TONERS DUE TO LEAKS IN THE YELLOW AND CYAN. AFTER I REPLACED THEM, THE MACHINE KEEPS GIVING ME AN EMPTY TONER ERROR MESSAGE. HELP!!... PS480D 20/24 pin Switching 480W Power Supply Name: swkargo Logisys 480W Power Supply This item states in can run -5vdc .It is NOT listed on the board or I beleive is r4 is missing the resitior. Any body have thid issue. Shawn
... Help needed Name: Ann Carter SanDisk 1TB Extreme Portable USB 3.1 When I click the link to download the user manual for my Sandisk Extreme external hard drive, it gives me the manual for the LG Cricket. Can you please change the link so I can download the Sandisk manual and begin using this drive? Thank you.... Line 6 Amplifi Name: David Nicoll Line 6 AMPLIFi FX100 Multi-Effects Guitar I have a line 6 Amplifi 100 and my problem is when i press switches ABCD to bank up and down nothing happens i have downloaded all up dates but still can not bank up down
Regards
David Nicoll ...
|
|