User Manual for APC SC450RMI1U Smart-UPS Uninterruptible Power Supply Click to enlarge the picture
Contents of the user manual for the APC SC450RMI1U Smart-UPS Uninterruptible Power Supply
- Product category: UPS Backup APC
- Brand: APC
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for APC UPS Backup
|
User manual for the APC SC450RMI1U Smart-UPS Uninterruptible Power Supply contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any APC product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official APC user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a APC product will considerably shorten its lifespan!
|
Product description The SC450RMI1U Smart-UPS Uninterruptible Power Supply from APC is a professional uninterruptible power supply designed to prevent blackouts, brownouts, sags, and surges from reaching your valuable equipment. It filters small utility line fluctuations and isolates your equipment from danger by internally disconnecting it from the utility line. When disconnected from the utility line, power is provided continuously from its internal battery until normal or safe conditions return or the battery is fully discharged. The UPS can be used in a tower or rackmount configuration. Front-access servicing also makes it easier to manage. This unit also offers RS-232 connectivity. It includes a $150,000 equipment-protection policy. - Power Protection & Backup
- Use this unit to protect your equipment from power surges, as well as ensure a continuous source of temporary backup power in case of emergencies.
- Rackmount or Tower
- This unit can be used in a desktop setting with a tower configuration, or can easily be converted to a rackmount unit by using the including rack brackets.
- Equipment Protection
- This model guarantees prevention of damage to your electronics with an equipment-protection policy.
UPC: 731304222712 In the Box APC SC450RMI1U Smart-UPS Uninterruptible Power Supply UPS Software CD Rackmount Brackets Smart UPS signalling RS-232 Cable Limited 2-Year Warranty Manual PDF 431.2kbessvxwcwac Table of Contents
|
Upload User Manual
Have you got an user manual for the APC SC450RMI1U Smart-UPS Uninterruptible Power Supply in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersAPC 450 Specs | | | Total Outlets | 4 x IEC-320 C13 | | Plug Type | NEMA 5-15P | | Data Line Protection | RJ45 | | Communications | Serial | | | | Maximum Wattage | 280 W | | Nominal Input Voltage | 230 VAC | | Input Voltage Adjustable Range | 151 to 302 VAC | | Input Frequency | 50/60 Hz ± 3 Hz (Auto Sensing) | | Nominal Output Voltage | 120 VAC | | Output Frequency | 50/60 Hz ± 3 Hz | | Voltage Distortion | <5% | | Load Capacity | 450 VA | | Crest Factor | 5:1 | | Waveform | Simulated Sine Wave | | | | Chemistry | Lead-Acid | | Full-Load Runtime | 5.9 Minutes | | Half-Load Runtime | 19.4 Minutes | | Charging Time | 5 Hours | | Replacement Battery | CURK18 RBC18 | | | | Cable Length | 6' / 1.8 m | | Material of Construction | Metal, Plastic | | Rack Form Factor | 1 RU | | Dimensions (W x H x D) | 1.7 x 17.0 x 15.2" / 33.0 x 432.0 x 385.0 mm | | Weight | 23.7 lb / 10.8 kg | | | | Package Weight | 27.85 lb | | Box Dimensions (LxWxH) | 23.0 x 16.0 x 6.0" |
Rating50% users recommend this product to others. And what about you?

This product has already been rated by 40 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
NEWER F100 CAMERA MONITOR... PhotoStage progessional... powerpint... Night Detective Quest 5M 5x Night Vision Monocular ... Ibanez AM93QM User Manual....
|
| Discussion |
Latest contributions to the discussion:
TR-P5TP pink robot dog Name: Allyson Top Race Race & Remote Control Hello we are having issues with the remote to the robot dog it just flashes a red light will not sync to the robot dog what so ever the dog is charged and batteries have been changed out more the once, Can i get help trouble shooting the issue or if something needs to be sent bac... Query Name: Libba Guyton Canon Pixma TS9520 Wireless All-In-One Printer Support Code 1851
Multi purpose tray guide is open. Close the guide and press OK.
Done and the same message continue to appear.... Manual Name: Grant Konus KonuStart-700B 60mm f 11.6 Refractor Please send user manual for Konustart-700B to above email address.... Fs3x manual Name: Randy Reid DigiTech FS3X Three-Function Foot Switch I need manual
... adding additional chime Name: Stan Stansfield OhmKat Video Doorbell Power Supply for The additional chime does not work and is closure to the transmitter then the first one. I plugged in the additional chime and set the volume and chime. The original chime works when the additional chime is plugged in to new location. The original chime is located further away bu...
|
|