User Manual for ARRI EB 6 9kW Electronic Ballast with ALF and DMX Click to enlarge the picture
Contents of the user manual for the ARRI EB 6 9kW Electronic Ballast
- Product category: Ballasts ARRI
- Brand: ARRI
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for ARRI Ballasts
|
User manual for the ARRI EB 6 9kW Electronic Ballast contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any ARRI product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official ARRI user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a ARRI product will considerably shorten its lifespan!
|
Product description The EB 6/9kW Electronic Ballast with ALF and DMX has been introduced by ARRI to power their innovative M90 6/9kW lamp head. This versatile power source has been streamlined and packed with features like CCL to compensate for power loss over long cable runs and ALF (Active Line Filter) which provides a higher Power Factor resulting in more efficient power use. This is accomplished by shifting the voltage and current waveforms in phase and minimizing harmonics and spikes. ALF also minimizes the current carried back on the neutral leg of the power systems.Since the M90 can accept either of Osram's 6 or 9kW lamps, the EB 6/9kW features automatic detection of both lamps and lamp heads. There's also a low noise mode and DMX on/off and 100-50% dimming control.To help you monitor the unit while shooting, it has LED indicators for input voltage, protective earth, over temperature, lamp on, detected lamp, and low noise mode as well as an illuminated on/off switch. - Attributes
-
- Constant lamp power and color temperature over the lifetime of the lamp
- Possibility to dim the light between 50 and 100%
- Low noise switch
- Active Line Filter - power factor correction
- Line over-voltage protection
- Protection from overheating
- Constant lamp power and color temperature over the lifetime of the lamp
- Less weight and size compared to magnetic ballasts
- At least 5% greater light intensity compared to magnetic ballasts
- At least 20% longer bulb life compared to magnetic ballasts
- Solid construction, including outside heat sinks as part of housing and a bumper at the operator control panel
- Special mechanical design for quick opening of the EB for service or maintenance
In the Box ARRI EB 6/9kW Electronic Ballast with ALF and DMX Power Cable with VEAM Connector Limited 1-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the ARRI EB 6 9kW Electronic Ballast with ALF and DMX in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersARRI EB 6/9 Specs | Type | Electronic ballast | | Lamp Power | 6.0 kW / 9.0 kW Automatic detection of 6 kW and 9 kW lamp and lamp head | | Input Voltage | 180-250 VAC, 50/60 Hz; 1,N,PE | | Input Current | 56 - 44 A | | Max. Apparent Power (VA) | 11200 VA | | Power Factor | Cos phi: approx. 0.98 | | Ignition | Cold strike and hot restrike | | Typical Light Ripple | < 3% | | Dimmer | 50 - 100% of the nominal value | | DMX | DMX 512 standard Functions: Ballast on/off; dimming of lamp power DMX Connector: XLR 5-pin male and female (in/out) | | Automatic Lamp Detection | Lamp and lamp head | | Current | Square wave: 75 Hz in Flicker-Free mode Nearly square wave: 50/60 Hz in 50 Hz resp. 60 Hz Mode | | Flicker Correction | Yes | | IP Rating | IP 21 | | Status Indication | LED Indication of: input voltage, protective earth, over temperature, lamp on, detected lamp, LED indication of low noise mode, illuminated on/off | | Noise Rating | 50 Hz and 60 Hz in Respective modes 75 Hz in Flicker-free mode | | Dimensions | 14 x 10.3 x 17.7" (35.8 x 26.3 x 45 cm) | | Weight | 62 lb (27 kg) |
Rating90% users recommend this product to others. And what about you?

This product has already been rated by 13 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Call Of Duty World War Two For Xbox... controller stratus XL... stratus XL... smart whatch serie S11 42mm... Allen & Heath SQ-6 manual...
|
| Discussion |
Latest contributions to the discussion:
AEW R 4100 Name: MAURICIO ANGARITA Audio-Technica AEW-R4100 UHF Diversity Receiver for AEW R 4100 has the mute function blocked and does not allow audio to pass. I tried several times to turn off the mute from the transmitter but it does nothing, the mute stays on. Solution?
Thank you... Instructions for assembling the 2015 Forecast Image Master Consoles GC3-A Name: mike elam Forecast Consoles GC3-A ImageMaster Editing Console Looking for instructions for assembling this console. ... EMPTY TONER ERROR MESSAGE AFTER REPLACING TONER Name: LINDA BAD YELLOW EYES Brother TN223BK Standard-Yield Toner I HAD TO CHANGE OUT ALL THREE TONERS DUE TO LEAKS IN THE YELLOW AND CYAN. AFTER I REPLACED THEM, THE MACHINE KEEPS GIVING ME AN EMPTY TONER ERROR MESSAGE. HELP!!... PS480D 20/24 pin Switching 480W Power Supply Name: swkargo Logisys 480W Power Supply This item states in can run -5vdc .It is NOT listed on the board or I beleive is r4 is missing the resitior. Any body have thid issue. Shawn
... Help needed Name: Ann Carter SanDisk 1TB Extreme Portable USB 3.1 When I click the link to download the user manual for my Sandisk Extreme external hard drive, it gives me the manual for the LG Cricket. Can you please change the link so I can download the Sandisk manual and begin using this drive? Thank you....
|
|