|
User Manual for Axis Communications T8612 Small Form Factor Pluggable LC.SX Module Click to enlarge the picture
Contents of the user manual for the Axis Communications T8612 Small Form Factor
- Product category: SFP Modules Axis Communications
- Brand: Axis Communications
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Axis Communications SFP Modules
|
User manual for the Axis Communications T8612 Small Form Factor contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Axis Communications product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Axis Communications user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Axis Communications product will considerably shorten its lifespan!
|
Product description Install the T8612 Small Form Factor Pluggable LC.SX Module from Axis Communications into an Axis switch or router to enable a fiber optic network connection. This SFP module provides network redundancy through its link-loss feature, which allows the system to recognize a lost connection between a specific device and the host. If available, this allows the downed device to redirect the transmission through a fallback connection. Able to reach speeds up to 1.25 Gbps, this multimode module features an LC duplex receptacle to transmit signals up to 1804'. It is able to operate in extreme temperatures from -40 to 185°F, making it suitable for most environments. - Multimode fiber optic transceiver module
- Complies with SFP Multisource Agreement (MSA)
- Installation does not interrupt network connection of host equipment
- Up to 1.25 Gbps speeds over fiber optic cable at distances up to 1804'
- Loss of Signal (LOS) feature allows the system to recognize a lost connection between a connected device and the host
In the Box Axis Communications T8612 Small Form Factor Pluggable LC.SX Module Limited 3-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the Axis Communications T8612 Small Form Factor Pluggable LC.SX Module in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersAxis Communications T8612 Specs | Compatibility | Axis products with SFP slots (available separately) | | Supported Protocols | Gigabit Ethernet | | Switching Capacity | 1.25 Gbps | | Transceiver Type | Multimode | | Compliance | Hot pluggability Wavelength 850 nm 1.0625 Gbps fibre channel FC-PI 100-M5-SN-I 1.0625 Gbps fibre channel FC-PI 100-M6-SN-I 1.25 Gbps IEEE 802.3z 1000Base-SX 1.25 Gbps IEEE 802.3ah 1000Base-SX | | Connector | LC duplex receptacle | | Approvals | EN 55022 Class B, EN 6100-3-2, EN 61000-3-3, EN 55024, FCC Part 15 Subpart B Class B, IEC/EN/UL 60950-1, EN 60825-1 Class 1, FDA 21 CFR 1040, RoHS, REACH, WEEE | | Distance | Up to 1804' (550 m) | | Compatible Cables | Fiber optic | | Operating Temperature | -40 to 185°F (-40 to 85°C) | | Operating Humidity | 10 to 90% RH, non-condensing | | Storage Temperature | -40 to 185°F (-40 to 85°C) | | Storage Humidity | 5 to 95% RH, non-condensing | | | | Package Weight | 0.09 lb | | Box Dimensions (LxWxH) | 4.5 x 2.55 x 1.1" |
Rating100% users recommend this product to others. And what about you?

This product has already been rated by 95 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Milano Carbon Fiber Tripod with B1 Head... c.PLASMA X LARGE SIN/SION user manual-pdf
centrotherm PECVD platform c.PLASMA... Streamlight Macrostream... AOC curved gaming monitor... User manual for Bowens ML500 Flash head ...
|
| Discussion |
Latest contributions to the discussion:
SQ 7 PDF Name: Yash Deshmukh Allen & Heath SQ-7 48-Channel 36-Bus I want to download PDF ... Business Card Studio 10 Name: Yvon Summitsoft Business Card Studio Pro Business Card Studio 10 will not print. Window 11
My printer will print anything else.... REQUESTING FOR QUOTE Name: ALBERT GABRIEL Auray X-Style Piano Bench & Double RFQ 919
S/ N DESCRIPTION UNIT QTY
1 KEYBOARD
YAMAHA MODEL
PSR-S750 61-KEY
DIGITAL
WORKSTATION PCS 1
2 AURAY DOUBLE-X
KEYBOARD
STAND WITH
PULL LOCK MFR
#KSPL-2X PCS 1
3 YAMAHA YBA-611
ARTISTE SERIES
KEYBOARD BAG
FOR 61-KEY
PORTABLE
KEYBOARDS PCS 1
4 AURAY FP-P1... Leatherman Micra Name: Rebecca Burgess Leatherman Micra Tool with Box Please send me a user's manual for Leatherman Micra... total cost of Casio CTK 3500 61 key manual Name: Eric Sensiba Casio CTK-3500 61-Key Keyboard with Touch What is the total cost for a Casio CTK 3500 61 key Electronic keyboard manual including taxes and shipping t85739?...
|
|