|
User Manual for Belden 2412 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable Click to enlarge the picture
Contents of the user manual for the Belden 2412 Multi-Conductor - Enhanced Category
- Product category: Bulk Video Cables Belden
- Brand: Belden
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Belden Bulk Video Cables
|
User manual for the Belden 2412 Multi-Conductor - Enhanced Category contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Belden product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Belden user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Belden product will considerably shorten its lifespan!
|
Product description The yellow 2412 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable from Belden is a 23 AWG Solid Bare Copper Conductor insulated with polyolefin. It is made up of a PVC (Polyvinyl Chloride) outer jacket and separated internally by dielectric tape. It has a ripcord, which is situated under the jacket of the cable. The cable is suitable for applications such as premises horizontal cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM. - The Cat 6 Cable is made up of a polyvinyl chloride outer jacket and separated internally by dielectric tape.
- It is compatible with premises horizontal cable, Gigabit Ethernet, 100 Base TX, 100 Base VG, 155 ATM, 622 ATM and any LAN.
UPC: 612825061151 Table of Contents
|
Upload User Manual
Have you got an user manual for the Belden 2412 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cable in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersBelden 2412004A1000 Specs | Pairs | 4 | | AWG | 23 | | Stranding | Solid | | Conductor Material | Bare copper | | Compatibility | Premises horizontal cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM | | Insulation Material | Polyolefin | | Outer Shield Material | Unshielded | | Outer Jacket Material | Polyvinyl Chloride | | Outer Jacket Diameter | 0.22" (0.56 cm) nominal | | Outer Jacket Ripcord | Yes | | Overall Cabling Separator Material | Dielectric tape | | Overall Nominal Diameter | 0.22" (0.56 cm) | | Pair Color Code Chart | - White/blue stripe and blue
- White/orange stripe and orange
- White/green stripe and green
- White/brown stripe and brown
| | NEC/(UL) Specification | CMR | | CEC/C(UL) Specification | CMR | | Other Standards | ISO/IEC 11801 ed 2.1 (2008) Class E | | EU CE Mark | Yes | | EU Directive 2000/53/EC (ELV) | Yes | | EU Directive 2002/95/EC (RoHS) | Yes | | EU RoHS Compliance Date | 01/01/2004 | | EU Directive 2002/96/EC (WEEE) | Yes | | EU Directive 2003/11/EC (BFR) | Yes | | CA Prop 65 (CJ for Wire and Cable) | Yes | | MII Order #39 (China RoHS) | Yes | | Telecommunications Standards | Category 6 - TIA 568.C.2 | | Other Specification | Third party verified to Category 6 | | Country Patent | US 6570095 US 6998537 US 7179999 US 7977575 | | Flame Test | UL1666 Vertical riser | | C(UL) Flame Test | FT4 | | CSA Flame Test | FT4 | | Plenum | No | | Plenum Number | 2413 | | Nominal Mutual Capacitance | 17.000 capacitance (pF/ft) | | Maximum Capacitance Unbalance | 330 (pF/100 m) | | Nominal Velocity of Propagation | 70 VP (%) | | Maximum Delay | 537 @ 100 MHz delay (ns/100 m) | | Max. Delay Skew | 45 delay skew (ns/100 m) | | Max Conductor DC Resistance | 8.2 DCR @ 68°F (20°C) (Ohm/100 m) | | Max. Operating Voltage - UL | 300 V RMS | | Maximum DCR Unbalanced | 5 DCR unbalance @ 68°F (20°C) (%) | | Storage Temperature Range | 68 to 167°F (-20 to 75°C) | | Installation Temperature Range | 41 to 122°F (5 to 50°C) | | Operating Temperature Range | 32 to 167°F (0 to 75°C) | | Max Recommended Pulling Tension | 40 lb (18.14 kg) | | Min. Bend Radius/Minor Axis | 1" (2.54 cm) | | Weight | 24 lbs (10.9 kg) | | | | Package Weight | 27.6 lb | | Box Dimensions (LxWxH) | 13.9 x 13.0 x 12.0" |
Rating70% users recommend this product to others. And what about you?

This product has already been rated by 88 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
NEWER F100 CAMERA MONITOR... PhotoStage progessional... powerpint... Night Detective Quest 5M 5x Night Vision Monocular ... Ibanez AM93QM User Manual....
|
|