|
User Manual for Bogen Communications SPLM Digital Sound Pressure Level Meter Click to enlarge the picture
Contents of the user manual for the Bogen Communications SPLM Digital Sound Pressure
- Product category: Metering Bogen Communications
- Brand: Bogen Communications
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Bogen Communications Metering
|
User manual for the Bogen Communications SPLM Digital Sound Pressure contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Bogen Communications product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Bogen Communications user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Bogen Communications product will considerably shorten its lifespan!
|
Product description The Bogen Communications SPLM Digital Sound Pressure Level Meter is used to measure SPL from 30 to 130dB. It is portable, easy-to-use, and appropriate for measuring and monitoring noise and sound in any environment. The SPLM Meter can be used for independent onsite readings or set to monitor and measure SPL variances in an area over a period of time. You can analyze the recorded measurements by connecting the meter to a PC or laptop, and using SoundLAB software (downloadable for free). - Removable windscreen filters out wind noise
- 1/2" condenser microphone
- Large 2.12" LCD screen with 4-digit readout
- Automatic backlight with light sensor
- AC analog signal output jack
- Pulse Width Modulation (PWM) output jack
- Fast/slow time weighting selections
- Wide measuring range of 30 to 130dB, including selectable 50dB dynamic ranges
- Calibration potentiometer
- Bar graph and over/under level indication
- AC frequency weighting selections
- Maximum value hold function to lock maximum reading
- Data record function with data full indicator
- Fixed screw mount for tripod use
- USB jack for connection to PC for data record downloading, real-time data sampling analysis, and printing graph and data functions 1
Please Note: Requires software freely downloadable from the Bogen website close - Calendar function (year, month, date) and time display (hour, minute, second) for SPL recordings
- Requires 4 AA batteries (included) with on-screen battery life indicator
- Designed to IEC 651 Type2 and ANSI S1.4 Type2 standards
In the Box Bogen Communications SPLM Digital Sound Pressure Level Meter Windscreen USB Connecting Cable Signal Output Wire 1.5V Alkaline Batteries Carrying Case Limited 1-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the Bogen Communications SPLM Digital Sound Pressure Level Meter in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersBogen Communications SPLM Specs | Measurement Range | 30 to 130 dB (AC) | | Level Range | 30 to 80, 50 to 100, 60 to 110, 80 to 130, 30 to 130 dB (AC) | | Accuracy | +/- 1.5 dB (reference sound pressure standard, 94 dB @ 1 kHz) | | Frequency Response | 31.5 Hz to 8.5 kHz | | Resolution | 0.1 dB | | Dynamic Range | 50 dB/100 dB (dependent on range) | | Overload | Indication: Over / Under | | Weighting | Frequency: A and C | | Time | Fast and Slow | | Display | 4 digits | | Analog Display | Bar Graph: 1 dB / bar (2 dB/bar for 30 to 130 dB range) | | Sampling Rate | 0.05 sec | | Output Signal | AC: 4 VRMS @ full bar graph Output Impedance: 600 Ω (3.5 mm connector) | | Calendar | Accuracy: +/- 30 seconds per day | | Data Storage | 4,700 points | | Auto Power Off | 10 minutes of no activity | | Microphone Type | 1/2" (12.7 mm) condenser | | Power Requirements | 4 AA alkaline battery (included), or 6 V external | | Battery Life | 10 hrs continuous use (alkaline batteries) | | Dimensions (W x H x D) | 2.7 x 9.4 x 1.4" (6.8 x 23.9 x 3.5 cm) | | Weight | 11.0 oz (311.8 g) (with batteries) | | | | Package Weight | 2.05 lb | | Box Dimensions (LxWxH) | 10.7 x 8.3 x 2.5" |
Rating20% users recommend this product to others. And what about you?

This product has already been rated by 96 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Expert intel sixcore i5-8400 4GHZ turbo... Color LaserJet Pro MFP M281fdw... call of duty world war II... Audio Technica AUDIO-AT8631
data sheet ... Sunpak Ultra 7000TM 2-1 tripod/monopod...
|
| Discussion |
Latest contributions to the discussion:
Query Name: Geoff Dibblee Carson zOrb Digital USB Microscope when useing the zorb it will not cover the whole of a stamp back or front as i am useing it for perfins stamps and whati have recived in the box just covers half a letter please can you help me to find away to enlarg the whole stamp
... Blown transformer Name: Dik Schouten Demeter VTDB-2 Single Channel Tube Direct Dear Sirs,where can i buy a new transformer for my VTDB 2b? If possible een 230 volt primary site...Y.S. Dik Schouten
... Battery charger light does not turn yellow or green when charging LP-E17 Name: DAVE Canon LC-E17 Charger for LP-E17 Battery I have a new Canon battery charger for EOS R10 Camera. It has lights that turn yellow and green when charging the Canon battery that came with the camera. But when I put in the BM battery LP-E17 no lights come on. I can tell the battery is charged when I put it in the camera, b... Stiff center dial wheel Name: Reynolds, Jane Tasco 10x50 Essentials Porro Binocular It is very hard for me to turn the center wheel with the ridges on it.
Could you please email me the user manual for the Tasco 10 x 50 mm zip focus? Thank you... Redfield 2-7x33 Name: Mike Redfield 2-7x33 Revolution Riflescope Can the elevation and windage knobs be reset to zero?
Thanks!...
|
|