User Manual for CyberPower PR750LCDRM1U Smart App Sinewave UPS Click to enlarge the picture
Contents of the user manual for the CyberPower PR750LCDRM1U Smart App Sinewave UPS
- Product category: UPS Backup CyberPower
- Brand: CyberPower
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for CyberPower UPS Backup
|
User manual for the CyberPower PR750LCDRM1U Smart App Sinewave UPS contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any CyberPower product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official CyberPower user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a CyberPower product will considerably shorten its lifespan!
|
Product description The CyberPower PR750LCDRM1U Smart App Sinewave UPS (750VA / 560W) features an LCD panel, offers sine wave output, and is Active-PFC-compatible for safeguarding mission-critical servers, telecom equipment and VoIP, and inter-networking hardware that requires seamless sine wave power. It incorporates microprocessor-based digital control and includes the PowerPanel Business edition software. The UPS system is ENERGY STAR qualified with GreenPower UPS Bypass circuitry to reduce energy consumption and heat build-up. - Suitable for servers, workstations, network devices, and telecom equipment
- Line-interactive topology
- Full AVR (Automatic Voltage Regulation) Buck/Boost
- AVR (Automatic Voltage Regulation) provides battery back-up power if the voltage drops below 80V or exceeds 150V
- SNMP/HTTP remote management
- 6 Outlets / USB, serial, and EPO ports
- PowerPanel Business software
- ENERGY STAR qualified and Active-PFC-compatible
UPC: 649532107506 In the Box CyberPower PR750LCDRM1U Smart App Sinewave UPS (750VA / 560W) 2 x Rackmount Bracket Emergency Power Off Cable (Gray) PowerPanel Business Edition Software CD Serial Interface Cable (DB-9) USB Type-A+B cable Limited 3-Year Warranty More from Manufacturer sutxscetzbxbtctezvyxvzsscyeadbt Table of Contents
|
Upload User Manual
Have you got an user manual for the CyberPower PR750LCDRM1U Smart App Sinewave UPS in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersCyberPower PR750LCDRM1U Specs | | | UPS Topology | Line-interactive | | Energy Saving | GreenPower UPS bypass technology | | | | Input Frequency | 50/60 Hz ± 3 Hz | | Voltage Range | 80 to 150 VAC | | Plug Type | NEMA 5-15P | | Plug Style | Right angled, 45° offset right | | Cord Length | 10' / 3 m | | | | VA | 750 | | Watts | 560 | | On Battery Voltage | 120 VAC ± 5% | | On Battery Frequency | 50/60 Hz ± 0.1 Hz | | On Battery Waveform | Sine wave | | Outlets | Total: 6 Battery & Surge Protected: 6 Critical Load: 2 | | Outlet Type | NEMA 5-15R | | Overload Protection | Internal circuitry limiting / circuit breaker | | Transfer time | 4 ms | | | | Runtime | 23 minutes at half load 7 minutes at full load | | Battery Type | Sealed lead-acid | | Battery Size | 6 V / 9 Ah | | Hot Swappable | Yes | | Replacement Battery | RB0690X4A | | User Replaceable | Yes | | Battery Quantity | 4 | | Typical Recharge Time | 8 hours | | | | Surge Suppression | 1780 joules | | | | LCD | Multifunction LCD Panel Load/Current Level, Runtime, Battery Level, Temperature (F & C), Battery In Use, Input Voltage, Output Voltage, Output Frequency, Overload, Wiring Fault, Battery Shutdown Voltage, Static Frequency Tolerance, Slew Rate, Silent Mode, Normal Mode | | HID Compliant USB Port | Yes | | Serial Port | Yes | | EPO Port | Yes | | Management Cable | USB, serial, and EPO | | LED Indicators | Power On, Wiring Fault | | Alarms | Audible: On Battery, Low Battery, Overload | | Software | PowerPanel Business edition | | SNMP/HTTP Remote Monitoring | Yes, with optional RMCARD202, RMCARD203 or RMCARD205 | | | | Operating Temperature | 32 to 104°F / 0 to 40°C | | Operating Humidity | 0 to 95% non-condensing | | Storage Temperature | 5 to 113°F / -15 to 45°C | | Maximum Operating Elevation | 10,000' / 3000 m | | Maximum Storage Elevation | 50,000' / 15,000 m | | Thermal Dissipation | AC Mode: 31 BTU/hr | | | | Safety | UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A | | Compliance | RoHS | | | | Rack Size | 1 RU | | Form Factor | Rack | | Dimensions (W x H x D) | 17.25 x 1.75 x 19.5" / 438.15 x 44.5 x 495.3 mm | | Weight | 40 lb / 18.14 kg | | | | Package Weight | 45.05 lb | | Box Dimensions (LxWxH) | 24.0 x 21.3 x 6.4" |
Rating70% users recommend this product to others. And what about you?

This product has already been rated by 11 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Swan Bread maker SWBBA7... Expert intel sixcore i5-8400 4GHZ turbo... Color LaserJet Pro MFP M281fdw... call of duty world war II... Audio Technica AUDIO-AT8631
data sheet ...
|
| Discussion |
Latest contributions to the discussion:
Query Name: Geoff Dibblee Carson zOrb Digital USB Microscope when useing the zorb it will not cover the whole of a stamp back or front as i am useing it for perfins stamps and whati have recived in the box just covers half a letter please can you help me to find away to enlarg the whole stamp
... Blown transformer Name: Dik Schouten Demeter VTDB-2 Single Channel Tube Direct Dear Sirs,where can i buy a new transformer for my VTDB 2b? If possible een 230 volt primary site...Y.S. Dik Schouten
... Battery charger light does not turn yellow or green when charging LP-E17 Name: DAVE Canon LC-E17 Charger for LP-E17 Battery I have a new Canon battery charger for EOS R10 Camera. It has lights that turn yellow and green when charging the Canon battery that came with the camera. But when I put in the BM battery LP-E17 no lights come on. I can tell the battery is charged when I put it in the camera, b... Stiff center dial wheel Name: Reynolds, Jane Tasco 10x50 Essentials Porro Binocular It is very hard for me to turn the center wheel with the ridges on it.
Could you please email me the user manual for the Tasco 10 x 50 mm zip focus? Thank you... Redfield 2-7x33 Name: Mike Redfield 2-7x33 Revolution Riflescope Can the elevation and windage knobs be reset to zero?