User Manual for CyberPower RMCARD305TAA Network Management Card Click to enlarge the picture
Contents of the user manual for the CyberPower RMCARD305TAA Network Management Card
- Product category: UPS Accessories CyberPower
- Brand: CyberPower
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for CyberPower UPS Accessories
|
User manual for the CyberPower RMCARD305TAA Network Management Card contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any CyberPower product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official CyberPower user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a CyberPower product will considerably shorten its lifespan!
|
Product description Remotely manage, monitor, and control select CyberPower UPS systems and ATS PDUs using a standard web browser, command line interface (CLI), SNMP, or network management system (NMS) with the RMCARD305TAA Network Management Card from CyberPower. This full-featured network management card provides Federal Trade Agreements Act (TAA) compliant power protection and is approved to be acquired by the United States government for use. This product is also compliant with GSA schedules.
CyberPower built the RMCARD305TAA to be especially suited for enterprise installation. It provides scheduling for UPS shutdown, startup, and rebooting, as well as event action settings, event logging, status recording, and automatic event notifications via email, SMS, SNMP traps, or Syslog. Furthermore, PowerPanel Business Edition Client software helps protect servers and workstations from data loss due to power failure by initiating auto-shutdown commands from a UPS when a power loss event occurs.
An optional environmental sensor (ENVIROSENSOR) can be connected to the RMCARD305TAA to monitor the ambient temperature and humidity of a server room, IT closet, or other critical environment. Administrators define temperature parameters in Fahrenheit or Celsius, and thresholds can be configured to prompt the RMCARD305TAA to send a predefined notifications. General Features - TAA Compliant
- CyberPower's TAA-compliant products are approved to be acquired by the United States government for use. These products are also compliant with GSA schedules.
- Environmental Sensor Compatibility
- The optional ENVIROSENSOR connects to the Universal port on the RMCARD305TAA to monitor ambient temperature and humidity. Notifications are enabled by default and alert thresholds can be easily customized to fit environmental control requirements.
- Remote Management
- Allows administrators to control and configure the UPS without being onsite via a standard web browser, command line interface (CLI), or network management system (NMS).
- Built-In Automatic Shutdown
- In conjunction with PowerPanel Business Edition Client, you can protect servers and workstations from data loss due to power failure.
- Offsite Scheduling of UPS and ATS PDU Operation
- Lets administrators conduct scheduled times for UPS and ATS PDU shutdown, startup, and reboot. Functionality includes event action management, event logging, and automatic event notification.
- Automatic Event Notification
- Provides immediate updates about power events via Email, SMS, SNMP Traps, or Syslog server.
- Event Logging and Status Records
- Traces the UPS and ATS PDU operational history, tracking events and input/output power status records.
- Event Action Settings
- Allows administrators to customize UPS actions in response to power and system events.
- Upgradable Firmware
- Keep the RMCARD305TAA up to date with the latest firmware version. New firmware releases include new functionality, feature enhancements, and bug fixes.
- Upgradable UPS Firmware
- Maintain UPS firmware that manages features and functions up to date to. The UPS firmware upgrade is easy to do via the web management interface. Select models only. Please contact your CyberPower rep for more information.
- Limited 3-Year Warranty
- Covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date.
Typical Applications CyberPower UPS Compatibility UPC: 649532619788 In the Box CyberPower RMCARD305TAA Network Management Card RJ45/DB9 Serial Port Connection Cable Spare Jumper Limited 3-Year Warranty (from date of purchase) Table of Contents
|
Upload User Manual
Have you got an user manual for the CyberPower RMCARD305TAA Network Management Card in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersCyberPower RMCARD305TAA Specs | | | Type | Network Management Card | | Network Port | Ethernet RJ45 | | Data Link Protocol | Ethernet 100Base-TX, Ethernet 10Base-T | | LED Status Indicators | Tx/Rx, Link | | Universal Port | Optional EVIROSENSOR | | | | HTTP | v1.1: RFC 2616 | | HTTPS | RFC 2818 | | SNMP | v1: RFC 1155, RFC 1156, RFC 1157 v3: RFC 3414 | | MIB | RFC 1213, RFC 1628 | | SMTP | RFC 2821 | | SMTPS | RFC 3207 | | TLS | v1.0: RFC 2246 v1.1: RFC 4346 | | SSL | v3.0: RFC 6101 | | Telnet | RFC 854 | | SSH | v2: RFC 4253, RFC 4254 | | FTP | RFC 959 | | DNS | RFC 1035 | | DHCP | RFC 2131 | | TCP/IP | v4: RFC 791 v6: RFC 2460 | | RADIUS | RFC 2865 | | LDAP | v3: RFC 2251 | | LDAPS | v3: RFC 4513 | | SysLog | RFC 5424 | | NTP | RFC 958 | | | | Operating Temperature | 32 to 104°F / 0 to 40°C | | Operating Relative Humidity | 0 to 90% (non-condensing) | | Operating Elevation | 0 to 10,000' / 0 to 3048 m | | Storage Temperature | 14 to 122°F / -10 to 50°C | | Storage Relative Humidity | 0 to 95% (non-condensing) | | Storage Elevation | 0 to 50,000' / 0 to 15,240 m | | | | Safety | FCC DoC Class A, CE | | Environmental | RoHS Compliant | | | | Dimensions | 2.6 x 1.7 x 5.3" / 6.6 x 4.3 x 13.5 cm | | Weight | 0.2 lb / 0.1 kg |
Rating50% users recommend this product to others. And what about you?

This product has already been rated by 80 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|