User Manual for Dorrough 40-A - Horizontal Rackmount Analog Loudness Meter Click to enlarge the picture
Contents of the user manual for the Dorrough 40-A - Horizontal Rackmount Analog
- Product category: Metering Dorrough
- Brand: Dorrough
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Dorrough Metering
|
User manual for the Dorrough 40-A - Horizontal Rackmount Analog contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Dorrough product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Dorrough user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Dorrough product will considerably shorten its lifespan!
|
Product description The Dorrough 40-A is a professional analog loudness meter, designed for modern stereo recording and broadcast requirements, and offering simultaneous average and peak program display, with separate ballistics and lightning-fast response. This meter is equipped with a 40-LED bar graph, showing 1dB of resolution per LED, and 14dB of headroom. - Rack or console mounted Analog Loudness Meter with dual dedicated ballistics for simultaneous peak and average readout
- Microchip processor with accuracy of oscilloscope, ultra-fast response time of 600ms average, virtually instantaneous peak for seamless continuous display of peak/average relationship
- Individual left and right XLR inputs for stereo mixing applications, +4 dB factory-calibrated
- Display with 40 LED's providing 1dB resolution per LED
- Proprietary "A" scale with 14dB of headroom
- XLR, 6 DIP switches for function assignments, mini 8-pin DIN port out for access to alarm relays, meter mode functions, and peak hold modes, standard with unit
In the Box Dorrough 40-A - Horizontal Rackmount Analog Loudness Meter Owner's Manual 1 Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the Dorrough 40-A - Horizontal Rackmount Analog Loudness Meter in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersDorrough 40-A Specs Input Impedance | 20 kOhm balanced 10 kOhm single-ended, +/- 2% | Common Mode Rejection Ratio | 80 dB at 60 Hz 60 dB at 20 kHz (balanced mode) | Input Sensitivity | -10 dB for full-scale display | Maximum Input Level | +24 dB before clipping | Signal Path Bandwidth | 10 Hz - 25 kHz, +/- .25 dB | Signal Path Distortion | >1% THD at 1 kHz, +24 dB input | Sum Error | >0.1 dB at 1 kHz | Difference Error | >0.1 dB at 1 kHz | Display Resolution | 40 LEDs, 1 dB/LED | Step Size Error | +/- 0.25 dB | Absolute Error | +/- 0.25 dB (Full Scale -39 dBu) | Drift | +/- 0.25 dB | Average Time Constant | 600 mS, +/- 6% | Peak Acquisition Period | 10 uS, to full-scale, sine input 25kHz | Peak Attack Period | Virtually Instantaneous | Peak Decay Period | 180 mS, from full-scale to all LEDs off | Display Update Rate | Approximately 10 mS | Display Duty Cycle | Display Time, AVERAGE, PEAK HOLD - 75% Display Time, PEAK - 100% | Power Supply Input Range | 117/237 VAC RMS, -20% to +10%, 50-60 Hz | Calibration Controls | None needed | User Controls | Left/Right input sensitivity Option DIP Switch: A) Peak Auto [ON] B) Difference Mode [ON/OFF] C) Over Level Alarm [ENABLE] D) Under Level Alarm [ENABLE] E) Auto ARMP | User Port | DB-9 Connector: A) Alarm relay closure contacts,1 form C, 1A, 30V AC or DC B) Mode control switch (user supplied) C) PEAK function switch (user supplied) | Dimensions (WxDxH) | 8.5 x 6.5 x 2.8" (215.9 x 165.1 x 71.1mm) | Weight | 2.3 lb (1.04 kg) | | Package Weight | 2.5 lb | Box Dimensions (LxWxH) | 10.787 x 7.402 x 3.858" |
Rating100% users recommend this product to others. And what about you?
This product has already been rated by 57 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
looking for a user manual for Quickbooks Premier Nonprofit 2020 for a Disabled American Veterans office.... Bower SFD9260.... 4-IN-1 WIRELESS CHARGER
... Brand :Gemini,model # XGA 4000,AND IT WAS PURCHASED NEW IN 2022,OR POSSIBLY EARLY 2023.WORKED perfect till one day I hit power switch and blew fuse x2... ZZSTAR binoculars...
|
Discussion |
Latest contributions to the discussion:
v18 Name: Craig Mcinturff Davis & Sanford Provista 7518B Tripod I am looking for a camera mounting plate for a v18 fluid head Davis & Sandford ... Impact SF-ABRL160 Flash stopped working Name: Sarah sananes Impact SF-ABRL160 Stand Mount Flash with Hello, our flash is connected to a canon camera and all of the sudden the flash is no longer working.
Does the flash have a certain battery life? ... REPEAT REQUEST AS YOU DID NOT ANSWER YOU JUST SENT ME MY MESSAGE BACK -PLEASE HELP Name: Tish Hopkins Benro TAD37C Series 3 Adventure Carbon Hi again-- all this did was send this email back to me with a link that brought me right back here... what is this?? also a link to search for manuals-- ive been there done that there is NO Manual to be found that answers my ? Please HELP thanks!!
Hi there is an extra small sc... Tripod heads DO NOT sit flush on the plate of the tripod Help Please Name: Tish Hopkins Benro TAD37C Series 3 Adventure Carbon Hi there is an extra small screw on the plate that the tripod head screws on that prevents my gimbal tripod head from sitting flush when it is screwed on. this is very annoying and does not allow my camera to stay steady when shooting. Please tell me how to resolve this issue. th... battery replacement Name: Danette L Boyd-Perez Doxie Go SE Portable Scanner Hello-- I have been working w/ support- it seems they sent incorrect battery replacement.
I confirmed DX-255 and was sent battery NP 120. There is no way that battery fits inside the panel of the DX-255. Please advise next steps thank you....
|
|