|
User Manual for ETC DMX RDM One-Port Touring Gateway Click to enlarge the picture
Contents of the user manual for the ETC DMX RDM One-Port Touring Gateway
- Product category: DMX Devices ETC
- Brand: ETC
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for ETC DMX Devices
|
User manual for the ETC DMX RDM One-Port Touring Gateway contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any ETC product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official ETC user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a ETC product will considerably shorten its lifespan!
|
Product description Useful in theaters, houses of worship, stage-manager panels, and system integration, the DMX/RDM One-Port Touring Gateway from ETC uses bi-directional communication over Ethernet with other network devices to send and receive DMX512 and RDM data, as well as ACN/sACN. The unit is powered by (PoE) Power over Ethernet or low-voltage DC power, using RJ45 for connection to a lighting network. The Gateway has Network, Power and Data indicators. Blue is for Power, Green is for Network, and Bi-Color is for DMX activity. The DMX port is software-configurable for input or output and can withstand fault voltages of up to 250VAC. - Applications
-
- Theaters
- Houses of worship
- High schools
- Tech table
- Stage-manager panels
- System integration
- Ideal for venues and applications where single DMXports are required with an Ethernet infrastructure
- Benefits
-
- One DMX/RDM connection using 5-pin male or female XLR
- Distributed DMX and RDM over Ethernet
- Supports Net3 protocol powered by ACN
- Distributes DMX and RDM data to any input/output device
- Powered using Power over Ethernet (PoE) or low-voltageDC power
- Power and Network status indicators
- Configurable using Net3 Concert software
- Compact single-gang size
In the Box ETC DMX/RDM One-Port Touring Gateway Backbox with Ethercon Connector and Hanging Bracket Limited 2-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the ETC DMX RDM One-Port Touring Gateway in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersETC 4264A1103 Specs | Functionality | Supports Net3/ACN (ANSI E1.31 and E1.17) Supports RDM (ANSI E1.20) USITT DMX512 and ANSI E1.11 DMX512-A compliant Advanced Input Patch (AIP) allows any incoming address tobe associated with any sACN address Flexible Output Patch (FOP) allows a 512-address universe tobegin at any output address Support for per-address or per-universe level priority | | Mechanical | Includes color matched ABS plastic faceplate Single-gang cover plate included One integrated DMX input or output port Network, power, and data activity LED indicators: - Blue power indicator - Green network activity indicator - Bi-color DMX activity indicator RJ45 for connection to lighting network Flush-mount using standard RACO 695 backbox Surface-mount backboxes available from ETC Backbox with Ethercon connector and hanging bracket included with portable version | | Environmental | Ambient Operating Temperature: 32 to 104° (0 to 40°) Operating Humidity: 5% - 95% non-condensing Storage Temperature: -40 to 158° (-40 to 70°C) | | DMX | Software-configurable for input or output Fully optically isolated input from gateway electronics Withstands fault voltages of up to 250 VAC Integrated DMX/RDM termination | | Configuration | Configuration using Net3 Concert Software Supports up to 512 DMX addresses per port 512 channels of data input or output Multiple sources may be combined to the network, with each source or address allowed an independent priority | | Dimensions | 6.3 x 4.5 x 3.5" (161 x 115 x 89 mm) | | Weight | 2.7 lb (1.23 kg) |
Rating80% users recommend this product to others. And what about you?

This product has already been rated by 97 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Expert intel sixcore i5-8400 4GHZ turbo... Color LaserJet Pro MFP M281fdw... call of duty world war II... Audio Technica AUDIO-AT8631
data sheet ... Sunpak Ultra 7000TM 2-1 tripod/monopod...
|
| Discussion |
Latest contributions to the discussion:
Query Name: Geoff Dibblee Carson zOrb Digital USB Microscope when useing the zorb it will not cover the whole of a stamp back or front as i am useing it for perfins stamps and whati have recived in the box just covers half a letter please can you help me to find away to enlarg the whole stamp
... Blown transformer Name: Dik Schouten Demeter VTDB-2 Single Channel Tube Direct Dear Sirs,where can i buy a new transformer for my VTDB 2b? If possible een 230 volt primary site...Y.S. Dik Schouten
... Battery charger light does not turn yellow or green when charging LP-E17 Name: DAVE Canon LC-E17 Charger for LP-E17 Battery I have a new Canon battery charger for EOS R10 Camera. It has lights that turn yellow and green when charging the Canon battery that came with the camera. But when I put in the BM battery LP-E17 no lights come on. I can tell the battery is charged when I put it in the camera, b... Stiff center dial wheel Name: Reynolds, Jane Tasco 10x50 Essentials Porro Binocular It is very hard for me to turn the center wheel with the ridges on it.
Could you please email me the user manual for the Tasco 10 x 50 mm zip focus? Thank you... Redfield 2-7x33 Name: Mike Redfield 2-7x33 Revolution Riflescope Can the elevation and windage knobs be reset to zero?
Thanks!...
|
|