User Manual for ETC Net3 N34G-4T Four-Port Gateway Rack-Mount Terminal Bundle Click to enlarge the picture
Contents of the user manual for the ETC Net3 N34G-4T Four-Port Gateway Rack-Mount
- Product category: DMX Devices ETC
- Brand: ETC
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for ETC DMX Devices
|
User manual for the ETC Net3 N34G-4T Four-Port Gateway Rack-Mount contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any ETC product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official ETC user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a ETC product will considerably shorten its lifespan!
|
Product description The ETC Net3 N34G-4T Four-Port Gateway Rack-Mount Terminal Bundle provides connection for up to four DMX lines and is designed for customers who do not need typical DMX connectors for lighting control of their permanently installed systems. The bare wire is mounted into the terminal ports using the provided terminal prep kit. Included in the bundle is the Gateway unit with 4 terminal strip modules, a rack mount, and a universal power supply. By default, the bundle comes with terminal connectors for DMX wire and the appropriate preparation kit. If you are connecting to Category 5 wire for DMX, request the DMX termination preparation kit with IDC connectors from ETC when purchasing this bundle. The Gateway is a configurable gate for essential DMX, sACN, and Remote Device Management data to be distributed throughout your entire network, ensuring not just basic control of your lights, but also peace of mind that all components are functioning as designed. Using bidirectional Ethernet communication the health of the data signal can be monitored. RDM is a protocol enhancement to DMX512 that allows bi-directional communication between a lighting or system controller and attached RDM-compliant devices over a standard DMX line. This protocol allows configuration, status monitoring, and management of these devices in such a way that does not disturb the normal operation of standard DMX512 devices that do not recognize the RDM protocol.The Gateway unit's LCD readout provides information on DMX terminal port, RDM, and network configurations. The modular design of the Net3 Gateway enables the user to tailor the number and type of inputs and outputs to suit a particular venue or location. The terminal strip module comes with ETC's standard DMX termination preparation kit, which includes instructions and all parts required for installation. This bundle provides the user with the ability to mount the Gateway into a standard 19" control rack slot. Two Gateways can be mounted side-by-side if required. The Gateway is fabricated from 16-gauge cold-rolled steel and finished in fine-texture, scratch-resistant black powder coat. - Supported Functions
-
- Supports Net3/ACN—ANSI E1.31 and E1.17
- Supports RDM—ANSI E1.20
- USITT DMX512 and ANSI E1.11 DMX512-A compliant
- Compliant with IEEE 802.3i for 10BASE-T, 802.3u for 100BASE-TX, and 802.3af for Power over Ethernet
- Advanced Input Patch (AIP) allows any incoming address to be associated with any sACN address
- Flexible Output Patch (FOP) allows a 512 address universe to begin at any output address
- Support for per-address or per-universe level priority
- Configuration
-
- Net3 Mode configuration provided by Gateway Configuration Editor (GCE) or directly from ACN
– Supports up to 512 DMX addresses per port – Supports up to 63,999 Streaming ACN universes - Up to 2048 channels in combination of data input and output
- DMX data input or output configurable by user
- Multiple outputs of a single DMX universe from a single gateway using a DMX splitter
- Supports discrete DMX universe outputs per port
- Multiple sources may be combined to the network with each source or address allowed an independent priority
- Individual port start address
- User configurable labeling
- Control Interface
-
- Backlit LCD display for Gateway identification, Network configuration, DMX port configuration, DMX port status, RDM Configuration
- Menu button for backlight/paging control
- Reset button for hard reset or forced reboot
- Front panel RJ45 for connection to lighting network
- Front and rear Power and Data indicators:
– Blue power indicators – Green network activity indicator In the Box ETC Net3 N34G-4T Four-Port Gateway Rack-Mount Terminal Bundle 19" Rack Mount Universal Power Supply ETC Standard DMX Termination Preparation Kit - Part Number 4100A012 Limited 3-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the ETC Net3 N34G-4T Four-Port Gateway Rack-Mount Terminal Bundle in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersETC 4260A1119 Specs | Power | IEEE802.3af Power over Ethernet 8 – 28 VDC external power supply Maximum Power Consumption: < 5 W | | Connectors | 4 x 8-pin terminal connectors 1 x RJ45 Ethernet DMX connector Terminal strip connector Fully optically-isolated input from the gateway electronics Integrated DMX/RDM termination | | Environmental | Ambient Operating Temperature: 32° to 104°F (0° to 40°C) Operating Humidity: 5 – 95% non-condensing CE compliant and ETL listed | | Data Signal | Maximum Delay Time from Input to Output: Not greater than one packet time—22 mS Selectable DMX refresh rate with a maximum < 40 Hz | | Dimensions | Gateway: 8.5 x 8.2 x 1.7" (21.5 x 21.0 x 4.5 cm) | | Weight | Gateway, Rack Mount, and Power Supply: 6 lb (2.7 kg) | | | | Package Weight | 6.0 lb | | Box Dimensions (LxWxH) | 15.0 x 12.5 x 3.4" |
Rating100% users recommend this product to others. And what about you?

This product has already been rated by 84 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Milano Carbon Fiber Tripod with B1 Head... c.PLASMA X LARGE SIN/SION user manual-pdf
centrotherm PECVD platform c.PLASMA... Streamlight Macrostream... AOC curved gaming monitor... User manual for Bowens ML500 Flash head ...
|
| Discussion |
Latest contributions to the discussion:
SQ 7 PDF Name: Yash Deshmukh Allen & Heath SQ-7 48-Channel 36-Bus I want to download PDF ... Business Card Studio 10 Name: Yvon Summitsoft Business Card Studio Pro Business Card Studio 10 will not print. Window 11
My printer will print anything else.... REQUESTING FOR QUOTE Name: ALBERT GABRIEL Auray X-Style Piano Bench & Double RFQ 919
S/ N DESCRIPTION UNIT QTY
1 KEYBOARD
YAMAHA MODEL
PSR-S750 61-KEY
DIGITAL
WORKSTATION PCS 1
2 AURAY DOUBLE-X
KEYBOARD
STAND WITH
PULL LOCK MFR
#KSPL-2X PCS 1
3 YAMAHA YBA-611
ARTISTE SERIES
KEYBOARD BAG
FOR 61-KEY
PORTABLE
KEYBOARDS PCS 1
4 AURAY FP-P1... Leatherman Micra Name: Rebecca Burgess Leatherman Micra Tool with Box Please send me a user's manual for Leatherman Micra... total cost of Casio CTK 3500 61 key manual Name: Eric Sensiba Casio CTK-3500 61-Key Keyboard with Touch What is the total cost for a Casio CTK 3500 61 key Electronic keyboard manual including taxes and shipping t85739?...
|
|