|
User Manual for ETC S123MCB Package Click to enlarge the picture
Contents of the user manual for the ETC S123MCB Package
- Product category: Dimmers ETC
- Brand: ETC
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for ETC Dimmers
|
User manual for the ETC S123MCB Package contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any ETC product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official ETC user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a ETC product will considerably shorten its lifespan!
|
Product description The ETC S123MCB Package includes the DRd6 Six-Module Power Enclosure with 12 Circuits, AX6 Auxiliary Rack Enclosure with 100A MCB (main breakers), and E-ACP Echo Architectural Control Processor. The DRd6 Six-Module Power Enclosure with 12 Circuits supports two processors and a variety of dimming, switching, and option modules. These rack enclosures are used with the included Auxiliary Rack Enclosure to provide local over-current protection and increased short-circuit current protection. Furthermore, the included Echo Architectural Control Processor works with the DRd6 Six-Module Power Enclosure to provide the flexibility of a modular power-control rack to any installation. With support for control stations, DMX input and Ethernet, the Echo Control Processor can be easily adapted per your needs. DRd6 Rack Enclosure - General
-
- High-density dimming for incandescent, fluorescent, neon, cold cathode, electronic, and magnetic low-voltage transformer load types
- Ability to cross bus and control two rack enclosures using one control processor
- Supports ETC Dimmer Doubling
- Designed for reliable, continuous operation
- Surface- or floor-stand mount
- Hinged, lockable full-height door with electrostatic air filter
- Integral low-voltage fan
- Modular control electronics
- All-On – clearly marked switch allows for all loads to be turned on to full, without the need for a control processor
- Protection from power spikes and surges with short-circuit current ratings from 22,000A up to 100,000A
- Monitoring and adjustment of incoming line voltage with min and max scale voltages
- UL924-Listed emergency-lighting bypass input with load shedding
- Dimming engine holds the last output during any loss of control
- Dimming engine boot time of less than four seconds
- Solid copper bus that easily converts from one phase to three-phase without additional parts
- Support for 16-bit DMX and over 65,000 steps of dimming
- Reverse-phase dimming control for electronic low-voltage transformers when used with the ELV module
- California Title 20/24 Compliant
AX6 Auxiliary Rack Enclosure - General
-
- Ability to cross bus two DRd Enclosures from one power feed
- Fine-textured, scratch resistant, epoxy paint
- Support for aluminum feeds in main breaker enclosures
- Equipped with breakers sized for maximum load capacity
E-ACP Echo Architectural Control Processor - General
-
- Designed for use with any EchoConnect-enabled station, sensor, or power controller
- Snapshot: Connect a DMX input, or set levels locally and then save to the preset with the touch of a button
- Plug and Play: Ready to go out of the box, no software or external programming required
- Secure-It User Access: Multiple levels of secure user access at the interface
- EchoConnect: Two-wire topology-free system provides the freedom to put stations where you need them
- NetConnect: Low-cost, easy-to-install Ethernet for data input from Net3 and sACN products
- USBConnect: Support for USB flash drives for configuration upload and download
- QuickLoad: SD media support for upload and backup of processor and DRd rack configuration data
- Support for up to 64 presets and 16 rooms
- Applications
-
- Houses of worship
- Education
- Hospitality
- Healthcare facilities
- Office buildings
- Conference rooms
- Meeting rooms
- Retail
In the Box ETC S123MCB Package DRd6 Six-Module Rack Enclosure with 12 Circuit AX6 Auxiliary Rack Enclosure with 100A MCB (Main Breakers) E-ACP Echo Architectural Control Processor Limited 3-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the ETC S123MCB Package in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersETC S123MCB PACKAGE Specs | | | Electrical | 100 to 120 V, three-phase systems Field configurable for single-phase operation with no additional parts ± 10% voltage tolerance 50 to 60 Hz operating frequency 22,000 A Short Circuit Current Rating (SCCR) 100,000 A SCCR when installed using AX Auxiliary Rack with Main Breaker Load terminals accept maximum #6 AWG wire | | Construction | Welded 18-gauge formed steel construction | | Environmental | Ambient Room Temperature: 32 to 104°F (0 to 40°C) Ambient Humidity: 10 to 90% non-condensing | | Certifications | UL and cUL Listed | | Dimensions | 21.9 x 17 x 9.6" (55.6 x 43 x 24 cm) | | Weight | 38 lb (17.2 kg) | | | | Electrical | 100,120, 240, and 277 V, 3-phase systems 120 V one phase systems ± 10% voltage tolerance High-Fault Short Circuit Current protection (MCB Only): 100,000 A (SCCR) at 120 V, 65,000 A (SCCR) at 240 and 277 V | | Construction | Welded 18-gauge formed steel construction | | Environmental | Ambient Room Temperature: 32 to 104°F (0 to 40°C) Ambient Humidity: 10 to 90% non-condensing | | Certifications | UL and cUL Listed | | Dimensions | 21.9 x 13 x 8" (55.6 x 33 x 20 cm) | | Weight | 28 lb (12.7 kg) | | | | Electrical | No discrete wiring connections required One ESTA DMX512A input and thru port Supports ANSI E1.31 (streaming ACN) EchoConnect communication bus Topology-free station wiring, utilizing Belden 8471 or equivalent, and one #14 ESD drain wire System configuration and programming information stored in non-volitile flash memory | | Environmental | Ambient Room Temperature: 32 to 104°F (0 to 40°C) Ambient Humidity: 10 to 90% non-condensing | | Certifications | UL and cUL LISTED, CE marked | | Dimensions | 2.6 x 12.2 x 5.9" (6.6 x 30.9 x 14.9 cm) | | Weight | 2.6 lb (1.2 kg) |
Rating80% users recommend this product to others. And what about you?

This product has already been rated by 87 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
Milano Carbon Fiber Tripod with B1 Head... c.PLASMA X LARGE SIN/SION user manual-pdf
centrotherm PECVD platform c.PLASMA... Streamlight Macrostream... AOC curved gaming monitor... User manual for Bowens ML500 Flash head ...
|
| Discussion |
Latest contributions to the discussion:
SQ 7 PDF Name: Yash Deshmukh Allen & Heath SQ-7 48-Channel 36-Bus I want to download PDF ... Business Card Studio 10 Name: Yvon Summitsoft Business Card Studio Pro Business Card Studio 10 will not print. Window 11
My printer will print anything else.... REQUESTING FOR QUOTE Name: ALBERT GABRIEL Auray X-Style Piano Bench & Double RFQ 919
S/ N DESCRIPTION UNIT QTY
1 KEYBOARD
YAMAHA MODEL
PSR-S750 61-KEY
DIGITAL
WORKSTATION PCS 1
2 AURAY DOUBLE-X
KEYBOARD
STAND WITH
PULL LOCK MFR
#KSPL-2X PCS 1
3 YAMAHA YBA-611
ARTISTE SERIES
KEYBOARD BAG
FOR 61-KEY
PORTABLE
KEYBOARDS PCS 1
4 AURAY FP-P1... Leatherman Micra Name: Rebecca Burgess Leatherman Micra Tool with Box Please send me a user's manual for Leatherman Micra... total cost of Casio CTK 3500 61 key manual Name: Eric Sensiba Casio CTK-3500 61-Key Keyboard with Touch What is the total cost for a Casio CTK 3500 61 key Electronic keyboard manual including taxes and shipping t85739?...
|
|