|
User Manual for FLIR TG56 Spot IR Thermometer with Thermocouple Input Click to enlarge the picture
Contents of the user manual for the FLIR TG56 Spot IR Thermometer with
- Product category: Thermal Inspection Cameras FLIR
- Brand: FLIR
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for FLIR Thermal Inspection Cameras
|
User manual for the FLIR TG56 Spot IR Thermometer with contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any FLIR product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official FLIR user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a FLIR product will considerably shorten its lifespan!
|
Product description The TG56 Spot IR Thermometer from FLIR provides non-contact surface temperature readings. This allows you to take measurements in places that are out of reach. Providing a distance-to-spot ratio of up to 30:1, the TG56 can measure smaller targets from a safer distance. New mode options give you control to view your current reading and last two temperature readings simultaneously. The TG56 is built with a color screen that makes it easy to navigate and select settings. It also features a thermocouple input. When using separately available thermocouple probe, you can measure the temperature difference between two junctions. -
- Easily identify measurement location with built-in laser targeting
- Graphical menu structure allows easy access to settings
- Easy emissivity selection with pre-determined levels and custom adjustment
- Visual high and low alarms
- Displays max/min values
- Supports differential mode (max - min)
- 6k pts running average
- Supports TC/IR differential mode
- Rugged, industrial design that can withstand a 3m drop
- Bright work light to help you see your target in low light conditions
- Tool-less battery compartment
UPC: 793950400562 In the Box FLIR TG56 Spot IR Thermometer with Thermocouple Input Wrist-Strap Lanyard 3 x AAA Battery General Purpose Type K Thermocouple Limited 5-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the FLIR TG56 Spot IR Thermometer with Thermocouple Input in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersFLIR TG56 Specs | | | Ratio | Distance to Spot Ratio: 30:1 | | Range | -22 to 1202°F (-30 to 650°C) | | Accuracy | ±1.8°F (±1°C) or 1% of reading | | Emission | Adjustable emissivity with 4 pre-sets and custom option | | Resolution | 0.1°F (0.1°C) | | Response | ≤150 ms | | Spectral Response | 5 to 14 microns | | Orientation | Laser: Single laser pointer to center of measurement spot, class 1 | | | | Type | General purpose type K thermocouple | | Range | Input Range: -22 to 1202°F (-30 to 650°C) Included Type K Thermocouple Probe Range: -22 to 572°F (-30 to 300°C) | | Accuracy | 3.6°F (±2°C) or 1% of reading | | Resolution | Measurement: 0.1°F (0.1°C) | | | | Type | TFT LCD | | Resolution | 128 x 128 | | Size | 1.45" (3.68 cm) | | | | Drop Resistance | Up to 9.8' (3 m) | | Certifications | CE / FDA laser | | | | Source | 3 x AAA alkaline | | Run Time | 8 hours maximum | | Auto Power Off | Yes with pre-set adjustment level and disable option |
Rating70% users recommend this product to others. And what about you?

This product has already been rated by 61 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
ESENIOR CG4-141-3CCT-BL-ZY
14" LED Light Bar... Cannon Pixma TS202 ... POSS PSHS60 CD Player in English... Romeo 5 red dot ... ImageBox 9MP Standalone film & photo convertor...
|
| Discussion |
Latest contributions to the discussion:
How do I disassemble the ends to trim the length of the product (THE VANGUARD MULTI-MOUNT6) ? Name: GUILLERMO HERNANDEZ Vanguard Multi-Mount 6 Tripod Utility Bar How do I disassemble the ends to trim the length of the product (THE VANGUARD MULTI-MOUNT6) ?... logitech extreme 3D pro Name: Al Wahba Logitech Extreme 3D Pro Joystick I want to activate the set with game flight simulator standard 2020 to contol the plane instrument... Cokin "A" Series Filter to "P" Series Holder Adapter Name: Mike Compton Cokin "A" Series Filter to "P" Hello, By chance, would you know where I can purchase a Cokin "A" Series Filter to "P" Series Holder Adapter? Thank you.... suction cup for windshield Name: Dave Seroka Papago GoSafe 30G Dash Camera with I am looking for a replacement suction cup for the windshield for my PapaGo safe 30G dash cam The one I have will not stick to the windshield. Could you send me information on where to get one... TR-P5TP pink robot dog Name: Allyson Top Race Race & Remote Control Hello we are having issues with the remote to the robot dog it just flashes a red light will not sync to the robot dog what so ever the dog is charged and batteries have been changed out more the once, Can i get help trouble shooting the issue or if something needs to be sent bac...
|
|