|
User Manual for FSR FL-500P-6-FRK Fire-Resistant Transformable Floor Box System Click to enlarge the picture
Contents of the user manual for the FSR FL-500P-6-FRK Fire-Resistant Transformable Floor Box
- Product category: Wall Plates & Installation Boxes FSR
- Brand: FSR
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for FSR Wall Plates & Installation Boxes
|
User manual for the FSR FL-500P-6-FRK Fire-Resistant Transformable Floor Box contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any FSR product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official FSR user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a FSR product will considerably shorten its lifespan!
|
Product description The FL-500P-6-FRK Fire-Resistant Transformable Floor Box System from FSR includes the FL-FRK-500P Floor Box and FL-FRK-500P FireStop Box Assembly Kit. The FL-500P-6-FRK Floor Box is UL listed and complies with UL 263 fire resistant rating and UL 514 scrub water protection requirements. It offers ample room to accommodate power, audio, video, telecommunications, and data cables. The FL-FRK Floor Box is affixed to the decking (available separately) by means of welding, or TEK screws. It is approved for installation using either light or normal weight concrete. The floor box height position can be adjusted accordingly to bring the floor box to the proper level before the pour. When the pour box cavity is filled, the concrete thickness around the floor box meets or exceeds the UL fire-resistant ratings of the floor. The floor box includes all the necessary internal plates and brackets to make pre and post concrete pour compartment changes quick and easy. The floor box features a rugged construction and is designed for use in carpet, tile or wood covered floors over poured concrete applications. It is suitable for ballroom conventions, and high-traffic areas. The FL-FRK-500P FireStop Box Assembly Kit includes four FL-FRK 1.5" Intumescent-Lined Conduit Assemblies, hardware, leveling feet, and 11-gauge steel temporary construction cover that protects the floor box interior during installation. The FL-500P-6-FRK Floor Box System allows implementing both high and low voltage gang configurations along with compartment isolation on the fly. This makes virtually any cabling/connector scenario possible. - Complete kit including floor box, pour pan, internal plates, brackets, and heat isolating conduits
- Includes a 11-gauge steel temporary construction cover
- Complies with UL 263 fire resistance rating
- Provides fire resistance up to 3 hours
- Removable center divider for passing cables through compartments
- Undivided capacity of up to 8-gang
- If divided any combination that totals 3 to 4 gangs per side in the box is permissible
In the Box FSR FL-500P-6-FRK Fire-Resistant Transformable Floor Box System FL-500P-6 Floor Box 4 x FL-FRK 1.5" Intumescent-Lined Conduit Assembly Leveling Feet Temporary Construction Cover Mounting Hardware Limited 1-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the FSR FL-500P-6-FRK Fire-Resistant Transformable Floor Box System in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersFSR FL-500P-6-FRK Specs | Capacity | Undivided: Up to 8 gang Divided: 3 to 4 gang per side | | Compliance | Fire Resistance: UL 263 Scrub Water Protection: UL 514 | | Resistance | Fire: Up to 3 h | | Dimension | Floor Box Depth: 6.0" (15.2 cm) Conduit Assembly (Ø x L): 1.5 x 8.1" (3.8 x 20.5 cm) |
Rating60% users recommend this product to others. And what about you?

This product has already been rated by 79 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
NEWER F100 CAMERA MONITOR... PhotoStage progessional... powerpint... Night Detective Quest 5M 5x Night Vision Monocular ... Ibanez AM93QM User Manual....
|
|