User Manual for Sennheiser MKH-8090 Compact Wide Cardioid Condenser Microphone Click to enlarge the picture
Contents of the user manual for the Sennheiser MKH-8090 Compact Wide Cardioid Condenser
- Product category: Small Diaphragm Condenser Sennheiser
- Brand: Sennheiser
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Sennheiser Small Diaphragm Condenser
|
User manual for the Sennheiser MKH-8090 Compact Wide Cardioid Condenser contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Sennheiser product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Sennheiser user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Sennheiser product will considerably shorten its lifespan!
|
Product description Part of the interchangeable 8000 series of professional microphones, the MKH 8090 from Sennheiser is a high-end, RF condenser microphone with a wide cardioid pick-up pattern. It consists of a microphone head and XLR module, and is an great main microphone for situations that demand a low level of acoustic space be included in the recording. It functions equally well as a support microphone when capturing larger groups of instruments. The microphone operates on the RF principle, delivering extremely low inherent self-noise, the ability to handle high sound pressure levels without distortion, and a high resistance to difficult climatic conditions, especially moisture. As part of the 8000 series, the capsule is sonically identical to other microphones in the series for sound consistency across the range. A number of optional modules are available, and when used with the MZD 8000 digital module (sold separately), the microphone functions as a digital microphone with all the benefits that such a configuration brings. - Wide cardioid pick-up pattern
- Wide frequency response from 30 Hz to 50 kHz
- Symmetrical transducer technology ensures low distortion
- Transformerless, fully floating balanced output
- Rugged metal housing with non-reflective Nextel coating
- Weatherproof due to high-frequency circuit
- Timbrally identical with the other 8000-series microphones for optimum aural compatibility
UPC: 615104263062 In the Box Sennheiser MKH-8090 Compact Wide Cardioid Condenser Microphone 2 x MKH 8090 Microphone Head 2 x MZX 8000 XLR Module for MKH-8000 Capsules 2 x MZQ-8000 Standard Microphone Clip for MKH-8000 Microphones 2 x MZW-8000 Windscreen for MKH8000 Series Microphones Carrying Case Limited 2-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the Sennheiser MKH-8090 Compact Wide Cardioid Condenser Microphone in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersSennheiser MKH 8090 Specs | | | Polar Pattern | Wide-Angle Cardioid | | Frequency Range | 30 Hz to 50 kHz | | Equivalent Noise Level | 13 dB A-Weighted 23 dB CCIR | | Maximum SPL | 142 dB SPL | | Impedance | 25 Ohms | | Load Impedance | 2000 Ohms | | | | Output Connectors | 1 x 3-Pin XLR | | Operating Current Consumption | 3.3 mA | | Operating Voltage | 48 V ± 4 V | | Operating Temperature | 14.00 to 140.00°F / -10 to 60°C | | Length | 2.95" / 75 mm | | Diameter | 0.75" / 19 mm | | Weight | 1.94 oz / 55 g | | | | Package Weight | 2.01 lb | | Box Dimensions (LxWxH) | 9.8 x 6.9 x 3.5" |
Rating60% users recommend this product to others. And what about you?

This product has already been rated by 99 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
M02 Ultra AI Smart Glasses, User's Manual... TLR-4 Streamlight instruction manual for this item ThankYou... NEWER F100 CAMERA MONITOR... PhotoStage progessional... powerpint...
|
| Discussion |
Latest contributions to the discussion:
TR-P5TP pink robot dog Name: Allyson Top Race Race & Remote Control Hello we are having issues with the remote to the robot dog it just flashes a red light will not sync to the robot dog what so ever the dog is charged and batteries have been changed out more the once, Can i get help trouble shooting the issue or if something needs to be sent bac... Query Name: Libba Guyton Canon Pixma TS9520 Wireless All-In-One Printer Support Code 1851
Multi purpose tray guide is open. Close the guide and press OK.
Done and the same message continue to appear.... Manual Name: Grant Konus KonuStart-700B 60mm f 11.6 Refractor Please send user manual for Konustart-700B to above email address.... Fs3x manual Name: Randy Reid DigiTech FS3X Three-Function Foot Switch I need manual
... adding additional chime Name: Stan Stansfield OhmKat Video Doorbell Power Supply for The additional chime does not work and is closure to the transmitter then the first one. I plugged in the additional chime and set the volume and chime. The original chime works when the additional chime is plugged in to new location. The original chime is located further away bu...
|
|