User Manual for Studio Projects C4 Small-Diaphragm Condenser Microphones Click to enlarge the picture
Contents of the user manual for the Studio Projects C4 Small-Diaphragm Condenser Microphones
- Product category: Small Diaphragm Condenser Studio Projects
- Brand: Studio Projects
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Studio Projects Small Diaphragm Condenser
|
User manual for the Studio Projects C4 Small-Diaphragm Condenser Microphones contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Studio Projects product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Studio Projects user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Studio Projects product will considerably shorten its lifespan!
|
Product description Sold in a matched pair, the Studio Projects C4 small-diaphragm condenser microphones exhibit the flexibility to excel in any recording and sound-reinforcement application. The C4's unique design features interchangeable capsules. Omnidirectional, cardioid, and hypercardioid capsules are provided for each microphone, introducing a wide array of application possibilities. A -10dB pad switch minimizes noise due to excessive transients and peaks, while a high-pass filter switch minimizes low-frequency noise and rumble. The cardioid capsules minimize off-axis noise and audio signal making them ideal for X/Y-style stereo capturing in live performances and recording applications, while the hypercardioid capsules provide even greater off-axis rejection. With the omnidirectional capsules, the mics are excellent pressure microphones and are capable of excellent audio reproduction during close capturing of instruments and vocals in favorable acoustic environments. The C4 pair is an excellent choice for capturing ambiance, piano, drum overheads, and more. - Matched Pair
- Dual C4 microphones are perfectly matched in signal and frequency response in order to achieve uniform, transparent audio reproduction
- Interchangeable Capsules
- Interchangeable omnidirectional, cardioid, and hypercardioid capsules provide the flexibility needed to excel in any recording or sound-reinforcement application
- -10 dB Pad Switch
- The -10 dB Pad switch provides added headroom, eliminating distortion due to signal overload
- High-Pass Filter
- A high-pass filter switch minimizes noise and rumble due to proximity effect, ambiance, etc
UPC: 850207000149 In the Box Studio Projects C4 Small-Diaphragm Condenser Microphones (Matched Pair) 2 x Cardioid Heads 2 x Omnidirectional Heads 2 x Hypercardioid Heads 2 x Foam Windscreens Limited 3-Year Warranty User Manual PDF 1.2mb Table of Contents
|
Upload User Manual
Have you got an user manual for the Studio Projects C4 Small-Diaphragm Condenser Microphones in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersStudio Projects C4 Specs | | | Transducer | Condenser | | Polar Pattern | Cardioid, Hypercardioid, Omnidirectional | | Pattern Selection | Switched | | Frequency Range | 20 Hz to 20 kHz | | Signal to Noise Ratio | 78 dB | | Equivalent Noise Level | 16 dB A-Weighted | | Maximum SPL | 140 dB SPL | | Pad | -10 dB -20 dB | | Impedance | 200 Ohms | | Load Impedance | 1200 Ohms | | Sensitivity | 12 mV/Pa | | Low-Cut Filter | 6 dB/Octave @ 75 Hz 6 dB/Octave @ 150 Hz | | Output Connectors | 1 x 3-Pin XLR | | Operating Current Consumption | 2 mA | | Operating Voltage | 48 V ± 4 V | | | | Package Weight | 4.0 lb | | Box Dimensions (LxWxH) | 13.5 x 10.0 x 5.0" |
Rating88% users recommend this product to others. And what about you?

This product has already been rated by 73 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
inspiron 3470... Film Scanner 8 mm + super 8 REELS MOVIE MAKER PRO... HP 3630 deskjet printer/scanner... Dell KB216 ITALIAN Slim Office Multimedia Keyboard BLACK.
... Mistral MC2300R 25L Detachable Air Coller with Steriliser.
Thank you in advance for your assistance.
Sincerely,
Jonathan Chua...
|
| Discussion |
Latest contributions to the discussion:
Hello from Murray - Gutkowski Name: Enos Greenholt Logitech Wireless Presenter R400 I tried to pepper it but got prune all over it.... Instructions for assembling the 2015 Forecast Image Master Consoles GC3-A Name: mike elam Forecast Consoles GC3-A ImageMaster Editing Console Looking for instructions for assembling this console. ... EMPTY TONER ERROR MESSAGE AFTER REPLACING TONER Name: LINDA BAD YELLOW EYES Brother TN223BK Standard-Yield Toner I HAD TO CHANGE OUT ALL THREE TONERS DUE TO LEAKS IN THE YELLOW AND CYAN. AFTER I REPLACED THEM, THE MACHINE KEEPS GIVING ME AN EMPTY TONER ERROR MESSAGE. HELP!!... PS480D 20/24 pin Switching 480W Power Supply Name: swkargo Logisys 480W Power Supply This item states in can run -5vdc .It is NOT listed on the board or I beleive is r4 is missing the resitior. Any body have thid issue. Shawn
... Help needed Name: Ann Carter SanDisk 1TB Extreme Portable USB 3.1 When I click the link to download the user manual for my Sandisk Extreme external hard drive, it gives me the manual for the LG Cricket. Can you please change the link so I can download the Sandisk manual and begin using this drive? Thank you....
|
|