User Manual for Vicon V1300X-IA Alarm Interface Click to enlarge the picture
Contents of the user manual for the Vicon V1300X-IA Alarm Interface
- Product category: Matrix Components Vicon
- Brand: Vicon
- Description and content of package
- Technical information and basic settings
- Frequently asked questions – FAQ
- Troubleshooting (does not switch on, does not respond, error message, what do I do if...)
- Authorized service for Vicon Matrix Components
|
User manual for the Vicon V1300X-IA Alarm Interface contain basic instructions
that need to be followed during installation and operation.
Before starting your appliance, the user manual should be read through carefully.
Follow all the safety instructions and warnings, and be guided by the given recommendations.
User manual is an integral part of any Vicon product,
and if it is sold or transferred, they should be handed over jointly with the product.
Following the instructions for use is an essential prerequisite for protecting
health and property during use, as well as recognition of liability on the part of the manufacturer
for possible defects should you make a warranty claim. Download an official Vicon user manual in which you will find instructions on how to install, use, maintain and service your product.
And do not forget – unsuitable use of a Vicon product will considerably shorten its lifespan!
|
Product description The V1300X-IA Alarm Interface (32 Inputs) from Vicon is a product that allows external alarm devices to be connected to Nova (VPS) digital control CPUs. Up to (32) alarms may be connected to this unit. Additional units may be cascaded for further expansion. When this unit senses a change in the status of one of its alarm inputs, it transmits the data to the VPS CPU, which in turn alerts the operator. It may also be programmed to execute an automatic response, such as displaying video from a camera associated with the alarm, causing a camera station to carry out a preset program or tour, or playing special alarm messages on the monitors, among other options. A single auxiliary relay output also activates when any alarm input goes active and may be used to control some external device such as a VCR or DVR. Alarm inputs are normally closed, but go active when the remote alarm switch opens or goes on active high. This unit's alarm inputs are CMOS/TTL compatible. Enabling and disabling individual alarm inputs is managed with software in the system CPU. This unit is compatible with all Nova (VPS) CPUs except VPS238, which has its own alarm interface. It connects to the CPU via a parallel data interface. - External Alarms with Nova
- This product allows external alarm devices to be connected to a Nova (VPS) digital control CPU.
- Expansion
- Additional units may be cascaded for further expansion.
- Automatic Responses
- This unit may be programmed to trigger automatic responses to alarms, such as switching to a camera or recording on an external VCR or DVR, among many other possibilities.
- CMOS/TTL Compatible
- This unit's alarm inputs are CMOS/TTL compatible.
UPC: 788654409904 In the Box Vicon V1300X-IA Alarm Interface (32 Inputs) Alarm Interface Three-Year Warranty Table of Contents
|
Upload User Manual
Have you got an user manual for the Vicon V1300X-IA Alarm Interface in electronic form? Please send it to us and help us expand our library of instruction manuals.
Thank you, too, on behalf of other users.
To upload the product manual, we first need to check and make sure you are not a robot. After that, your "Submit Link" or "Upload File" will appear.
Technical parametersVicon V1300X-IA Specs | Input | Alarm Inputs: x32 normally closed (NC) or TTL low | | Output | Alarm Output: Signal sent to CPU when alarm input is detected Auxiliary Output: Dry contact relay activates when alarm input is detected | | Construction | Steel | | Finish | Black, metal | | Connectors | Alarm Inputs: x4 16-pin removable screw terminal blocks Output to CPU: 37-pin D-shell connector Aux Output: 3-pin removable screw terminal block Power: Detachable 3-conductor cable with grounded plug | | Indicators | Red LED on front panel | | Power | Input Power: 32 inputs, 120V Power Consumption: 15W Heat Equivalent: 0.85 BTU/min (0.21 cal/min) Input Signal: Alarmed: Contacts open or active high TTL high = 2.7 to 5.3V Secured: Contacts closed or active low TTL low = 0.0 to 0.7V Auxiliary Relay: Dry contact relay rated at: 1.0A at 24VDC or 0.5A at 115VAC Fuse: 120V models: 0.75A, 250V, 5mm Radio-Frequency Emission Standard: FCC Class A European Community (CE) Standard: EN 50081-1 generic emissions EN 50082-1 generic immunity | | Dimensions (HxWxD) | 3-1/2 x 19 x 7" (8.81 x 48.3 17.8cm) | | Weight | 9.0 lbs (4.1kg) | | | | Package Weight | 10.75 lb | | Box Dimensions (LxWxH) | 20.2 x 12.7 x 7.5" |
Rating100% users recommend this product to others. And what about you?

This product has already been rated by 84 owners. Add your rating and experience with the product.
Discussion
Ask our technicians if you have a problem with your settings,
or if anything is unclear in the user manual you have downloaded.
You can make use of our moderated discussion.
The discussion is public and helps other users of our website who may be encountering similar problems.
The discussion is empty - enter the first post
Post a new topic / query / comment:
|
|
|
| Request for user manual |
You can’t find the operation manual you are looking for? Let us know and we will try to add the missing manual:
I’m looking for a manual / Request for manual
Current requests for instruction manuals:
NEWER F100 CAMERA MONITOR... PhotoStage progessional... powerpint... Night Detective Quest 5M 5x Night Vision Monocular ... Ibanez AM93QM User Manual....
|
| Discussion |
Latest contributions to the discussion:
TR-P5TP pink robot dog Name: Allyson Top Race Race & Remote Control Hello we are having issues with the remote to the robot dog it just flashes a red light will not sync to the robot dog what so ever the dog is charged and batteries have been changed out more the once, Can i get help trouble shooting the issue or if something needs to be sent bac... Query Name: Libba Guyton Canon Pixma TS9520 Wireless All-In-One Printer Support Code 1851
Multi purpose tray guide is open. Close the guide and press OK.
Done and the same message continue to appear.... Manual Name: Grant Konus KonuStart-700B 60mm f 11.6 Refractor Please send user manual for Konustart-700B to above email address.... Fs3x manual Name: Randy Reid DigiTech FS3X Three-Function Foot Switch I need manual
... adding additional chime Name: Stan Stansfield OhmKat Video Doorbell Power Supply for The additional chime does not work and is closure to the transmitter then the first one. I plugged in the additional chime and set the volume and chime. The original chime works when the additional chime is plugged in to new location. The original chime is located further away bu...
|
|